CN

Home/ Product/ SDC-1200Desktop high temperature contact angle measuring instrument

SDC-1200Desktop high temperature contact angle measuring instrument

Product Comparison

SDC-1200列表图片.png

SDC-1200Desktop high temperature contact angle measuring instrument

Desktop high temperature contact angle measuring instrument, which can measure the contact angle and surface tension of molten metals under high temperature and high vacuum.

Equipment overall parameters
model numberSDC-1200 typetabletophigh temperature
Acquisition System
CCDSONY high-speed industrial-grade chip, 1.3 million pixels, 25 frames/S
camera lens0.7-4.5 times high-definition telefocal length industrial microscope
Acquisition system adjustmentOptical imaging tilt, -10~10° continuously adjustable
Light source system
light sourceDense LED adjustable blue tone industrial grade cold light source
service lifeMore than 25,000 hours
High temperature system
temperature control rangeNormal temperature to 1700°C under normal pressure, normal temperature to 1500°C under vacuum conditions
Heating systemSilicon molybdenum rod heating element, constant temperature zone length 120mm, intelligent 30-segment programmable temperature control
Heating pipeOuter diameter 60mm, inner diameter 50mm, length 1000mm
Temperature measurement systemDual temperature monitoring system, both external and built-in, measurement accuracy ±1°C
window flangeCoaxial double window flange device for contact angle test, built-in vacuum system and protective gas pipeline, built-in double water cooling device
Professional base material for brazing experimentSupporting special materials for brazing experiments
Vacuum system/Gas protection
Vacuum rangePrecision molecular pump, room temperature can reach 10^(-5)Pa, vacuum 10^(-3)Pa
Vacuum measuring rangeMeasuring range105~10-7Pa, full scale high precision vacuum gauge
Gas protection systemEquipped with dual-channel inert protection device, which can use a process gas simultaneously or separately to protect the internal metal
Cooling system
Temperature control range5-35℃
External dimensions(L*W*H)460*380*590mm
water pump flow15L/min Cooling system capacity≥11L
actual cooling capacity1520W
Software function
Contact angle measurementHigh temperature contact angle measurement method; 30 segment high temperature settings (software intelligently sets temperature segments and controls temperature)
surface free energySurface energy calculation; adhesion work, spreading coefficient

{{item.Title}}{{item.subtitle}}

{{item.Info}}

Add product

Please select the product you would like to add to compare

{{item.Title}}

{{item.Info}}

TOP